Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
ESC Heart Fail ; 2023 Apr 19.
Article in English | MEDLINE | ID: covidwho-2299948

ABSTRACT

AIMS: Left ventricular assist devices (LVADs) support the hearts of patients with advanced heart failure. Following LVAD implantation, patients face a complex regimen of self-care behaviours including self-care maintenance, self-care monitoring and self-care management. However, during the COVID-19 pandemic, symptoms of anxiety and depression may have interfered with their self-care. Currently, little is known on how specific self-care behaviours of LVAD-implanted patients changed during the COVID-19 pandemic. We aim to describe the changes in self-care behaviours among patients with an implanted LVAD in Israel during the COVID-19 pandemic and explore the factors related to self-care behaviour change. METHODS: A prospective observational cross-sectional study design. A convenience sample of 27 Israeli LVAD-implanted patients (mean age 62.4 ± 9, 86% male, 78.6% living with a partner) completed the LVAD Self-Care Behaviour Scale (1 = never to 5 = always) and Hospital Anxiety and Depression Scale (0 = not at all to 3 = most of the time). Data were collected before and after the onset of the COVID-19 pandemic in Israel. Statistical analyses included paired t-tests, Pearson's correlations, and one-way repeated measures ANOVAs. RESULTS: During the COVID-19 pandemic, a significant decrease was found in patients' adherence to checking and recording their LVAD speed, flow, power and PI (Pulsatility Index) (P = 0.05), checking their INR (P = 0.01), and daily weighing (P < 0.01). The prevalence of some behaviours (e.g. regularly exercising) increased in some patients and decreased in others. Patients living without a partner worsened their adherence to some of the self-care behaviours (e.g. taking medicines as prescribed), compared with those living with a partner (Mb  = 5.0 ± 0 and Md  = 5.0 ± 0, delta = 0 vs. Mb  = 5.0 ± 0 and Md  = 4.6 ± 0.9, delta = -0.4, respectively; F = 4.9, P = 0.04). Women, and not men, tended to improve their adherence to the self-care behaviour such as avoiding kinking, pulling, or moving the LVAD driveline at the exit site (Mb  = 4.0 ± 1.0 and Md  = 5.0 ± 0, delta = 1.0 vs. Mb  = 4.5 ± 0.9 and Md  = 4.4 ± 1.2, delta = -0.1, F = 4.7, P = 0.04, respectively). In total, 41% (11) patients reported neither anxiety nor depression, 11% (3) reported anxiety, 15% (4) reported depression, and 44% (12) reported both anxiety and depression. No associations between anxiety and/or depression and self-care behaviours were found. CONCLUSIONS: Priorities in self-care behaviours among patients with implanted LVAD changed after the onset of the COVID-19 pandemic. Factors that assisted with adherence to self-care behaviours included living with a partner and being female. The current results may guide further research on identifying behaviours that are at risk of not being maintained during a time of emergency.

2.
Ann Thorac Surg ; 2022 Nov 30.
Article in English | MEDLINE | ID: covidwho-2237391

ABSTRACT

The thirteenth annual report from The Society of Thoracic Surgeons (STS) Interagency Registry for Mechanically Assisted Circulatory Support (Intermacs) highlights outcomes for 27,314 patients receiving continuous flow durable left ventricular assist devices (LVAD) over the last decade (2012-2021). In 2021, 2,464 primary LVADs were implanted, representing a 23.5% reduction in the annual volume compared to peak implantation in 2019 and an ongoing trend from the prior year. This decline is likely a reflection of the untoward effects of the COVID-19 pandemic and the change in the US heart transplant allocation system in 2018. The last several years have been characterized by a shift in device indication and type with 81.1% of patients now implanted as destination therapy and 92.7% receiving an LVAD with full magnetic levitation in 2021. However, despite an older, more ill population being increasingly supported pre-implant with temporary circulatory devices in the recent (2017-2021) vs prior (2012-2016) eras, the 1- and 5-year survival continues to improve at 83.0% and 51.9%, respectively. The adverse events profile has also improved, with significant reduction in stroke, gastrointestinal bleeding, and hospital readmissions. Finally, we examined the impact of the change in heart transplant allocation system in 2018 on LVAD candidacy, implant strategy, and outcomes. In the competing outcomes analysis, the proportion of transplant eligible patients receiving a transplant has declined from 56.5% to 46.0% at 3 years, while the proportion remaining alive with ongoing support has improved from 24.1% to 38.1% at 3 years, underscoring the durability of the currently available technology.

3.
J Card Surg ; 2022 Nov 08.
Article in English | MEDLINE | ID: covidwho-2108104

ABSTRACT

BACKGROUND: Coronavirus (COVID-19) infection exposes patients with heart failure specially who are on mechanical support to a higher risk of morbidity and mortality. AIMS: To investigate the impact of COVID-19 infection on left ventricular assist device (LVAD) thrombosis in heart failure patients. MATERIALS & METHODS: We searched the medical electronic records, Medline, PubMed and Cochrane databases for; (LVAD) AND (thrombosis)) AND (covid-19)) AND (heart failure). We divided cases reported into, LVAD thrombosis with COVID-19 infection and compare them with LVAD thrombosis without COVID-19 infection. Demographic data, LVAD device, presentation, treatment and outcomes were reviewed in all the LVAD thrombosis patients. RESULTS: In addition to our case, 8 other cases of LVAD thrombosis associated with COVID and 9 cases of LVAD thrombosis without covid infection were found. Patients with Covid infection had worse presentation and outcomes (3 deaths VS. 1 death in non-covid group). DISCUSSION: In LVAD patients, pump malfunction due to thrombus development in the inflow cannula, device body, or outflow graft can result in hemodynamic instability, hemolysis and other life-threatening complications. COVID infection significantly increases the risk of mortality in LVAD patient by accelerating the pump thrombosis due to elevated levels of endothelial protein C receptor and thrombomodulin along with procoagulants such as factor VIII, P-selectin, and von Willebrand factor. CONCLUSION: Significant morbidity and mortality are attributed to LVAD thrombosis, which are exasperated by prothrombotic conditions created in COVID-19 infections.

4.
Am Heart J Plus ; 24: 100223, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-2094982

ABSTRACT

Background: Patients with heart failure face increased morbidity and mortality when infected with COVID-19. The objective of this study was to evaluate the outcomes of patients with Heart Failure (HF), Left Ventricular Assist Devices (LVADs), or Heart Transplants (HTx) diagnosed with COVID-19 within an advanced HF practice. Methods: Out of 2635 patients followed, 96 patients were diagnosed with COVID-19 between March 2020 and January 2021. Median hospital length of stay (LOS), requirement for mechanical ventilation (MV), and mortality rate were evaluated. Results: The distribution of COVID-19 among the 96 patients was: HF = 43 (45 %), LVAD = 16 (17 %) and HTx = 37 (38 %). Among 43 HF patients, 5 (12 %) died, 18 (42 %) required hospitalization with an LOS of 7 days, 5 (12 %) required ICU and 4 (9 %) required MV. Of the 16 LVAD patients, 2 (13 %) died, 8 (50 %) required hospitalization with an LOS of 11 days, 3 (19 %) required ICU and 3 (19 %) required MV. Among 37 HTx patients, 7 (19 %) died, 23 (62 %) required hospitalization with an LOS of 9 days, 6 (16 %) required ICU and 6 (16 %) required MV. Conclusion: This report is among the first to describe the impact of COVID-19 on a diverse advanced HF practice. It highlights the risks associated with COVID-19 faced by the HF, LVAD and HTx patients. A 90-day mortality rate of 19 % with HTx patients acquiring COVID-19 is ominous as is a mortality rate of 12 % each for HF and LVAD patients. This clinical impact should serve as a reminder of unique challenges with these populations.

5.
Cureus ; 14(4): e24477, 2022 Apr.
Article in English | MEDLINE | ID: covidwho-1876134

ABSTRACT

Myocarditis was identified as a rare but serious adverse event that can occur after mRNA-based coronavirus disease 2019 (COVID-19) vaccination, particularly in young males. During the COVID-19 pandemic, we report a case of a young obese male without multiple comorbidities who presented with abdominal pain and was found to have severe myocarditis/cardiomyopathy, which was likely due to mRNA-based COVID-19 vaccination. The patient had left ventricular assist device (LVAD) implantation during hospitalization. Myocarditis/cardiomyopathy may be a rare complication of the mRNA-based COVID vaccine; however, one should maintain a high index of suspicion that these vaccines may cause irreversible cardiomyopathy if the patient had prior COVID-19 infection.

6.
J Cardiothorac Vasc Anesth ; 36(8 Pt A): 2439-2445, 2022 08.
Article in English | MEDLINE | ID: covidwho-1611007

ABSTRACT

OBJECTIVES: To describe angiotensin II (ANGII) use in patients on mechanical circulatory support (MCS). To evaluate the efficacy and safety of ANGII in patients with shock on MCS. DESIGN: Retrospective cohort study. SETTING: A single-center, quaternary care academic medical center. PARTICIPANTS: The study comprised critically ill patients on MCS. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Fourteen patients were included in this retrospective analysis. The median age was 54 years (44.8, 68.3) and 78.6% were men. Six patients were receiving venoarterial extracorporeal membrane oxygenation support, 4 patients were receiving venovenous extracorporeal membrane oxygenation support, and 4 patients were on left ventricular assist devices. Five patients (36%) achieved hemodynamic response to ANGII at 3 hours, defined as a mean arterial pressure (MAP) of ≥65 mmHg or a 10-mmHg increase in MAP with a decrease or no change in total vasopressor dose. Overall, the median MAP increased from 61 mmHg (51, 73) at baseline to 66 mmHg (58, 71) at 3 hours, and the median norepinephrine dose decreased from 0.45 µg/kg/min (0.28, 0.6) at baseline to 0.2 µg/kg/min (0.18, 0.32) at 3 hours. The in-hospital mortality rate was 78.6%. Two patients experienced severe adverse drug events and 1 patient had a sentinel thrombotic event. CONCLUSIONS: This study suggested that ANGII may provide a salvage treatment option in patients on MCS with refractory vasodilatory shock. There are several safety considerations with the use of ANGII in these patients. Prospective randomized controlled trials are needed to evaluate the safety and efficacy of ANGII in patients on MCS.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Shock , Angiotensin II , Female , Humans , Male , Middle Aged , Prospective Studies , Retrospective Studies , Shock/etiology , Shock/therapy , Shock, Cardiogenic
7.
Curr Anesthesiol Rep ; 11(4): 421-428, 2021.
Article in English | MEDLINE | ID: covidwho-1453924

ABSTRACT

Purpose of Review: Owing to increased utilization of Mechanical Circulatory Support (MCS) devices, patients with these devices frequently present for surgeries requiring anesthetic support. The current article provides basics of perioperative management of these devices. Recent Findings: Use of extracorporeal membrane oxygenation (ECMO) and left ventricular assist devices (LVADs) are on the rise with recently updated management guidelines. Veno-venous ECMO utilization has been widely utilized as a salvage therapy during the COVID-19 pandemic. Summary: Intra-Aortic Balloon Pumps continue to be one of the most frequently used devices after acute myocardial infarction. ECMO is utilized for pulmonary or cardiopulmonary support as salvage therapy. LVADs are used in patients with end-stage heart failure as a destination therapy or bridge to transplant. Each of these devices present with their own set of management challenges. Anesthetic management of patients with MCS devices requires a thorough understanding of underlying operating and hemodynamic principles.

8.
J Artif Organs ; 25(2): 148-154, 2022 Jun.
Article in English | MEDLINE | ID: covidwho-1333076

ABSTRACT

Coronavirus disease 2019 affected millions of people and caused pneumonia, acute respiratory distress syndrome and increased mortality worldwide. Data from multicenter studies showed that concomitant chronic diseases are associated with severe coronavirus disease. Patients with left ventricular assist device (LVAD) support may also be vulnerable to the disease. Some symptoms of COVID-19 infection like dyspnea and fatigue can overlap with heart failure or LVAD dysfunction. Careful evaluation should be made to diagnose and treat these patients. In these two cases with COVID-19, here we presented the first two patients supported with LVAD in Turkey.


Subject(s)
COVID-19 , Heart Failure , Heart-Assist Devices , Respiratory Distress Syndrome , COVID-19/complications , Heart Failure/complications , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Humans , Respiratory Distress Syndrome/diagnosis , Respiratory Distress Syndrome/etiology , Respiratory Distress Syndrome/therapy , Treatment Outcome
9.
Transpl Infect Dis ; 23(4): e13681, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-1295140

ABSTRACT

INTRODUCTION AND OBJECTIVES: Patients awaiting heart transplantation (HTx) are at increased risk developing severe coronavirus disease 2019 (COVID-19). Patients supported by a left ventricular assist device (LVAD) face additional risks due to coagulopathies during COVID-19. Following HTx, elevated risk factors for severe COVID-19 persist due to chronic immunosuppression and frequent comorbidities. Taken together, COVID-19 vaccination is of critical importance in all three patient cohorts. Here, we report our experience to deliver COVID-19 vaccination in a German transplant center. METHODS AND RESULTS: We screened 211 patients for contraindications and offered the remaining 186 eligible patients COVID-19 vaccination. Of those, 133 patients (71%) accepted the offer and were vaccinated. Acceptance of vaccination differed between HTx recipients (84 of 113, 74%), patients on the waiting list (34 of 47, 72%), and patients with LVAD support (28 of 50, 56%). The LVAD cohort demonstrated lower acceptance levels for vaccination compared to HTx recipients and patients awaiting HTx (74% vs. 56%; p = 0.028). CONCLUSION: We demonstrate for the first time only moderate acceptance levels of COVID-19 vaccination in HTx recipients and candidates on the waiting list compared to general population, despite perceived high-risk for severe disease. Additionally, those supported by LVAD have even lower adherence. Efforts may need to be made to increase acceptance in this vulnerable as well as cost-intensive patient cohort.


Subject(s)
COVID-19 , Heart Failure , Heart Transplantation , Heart-Assist Devices , COVID-19 Vaccines , Heart Transplantation/adverse effects , Heart-Assist Devices/adverse effects , Humans , SARS-CoV-2 , Treatment Outcome , Vaccination
10.
J Card Surg ; 36(10): 3491-3493, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1295078

ABSTRACT

Patients with end-stage congestive heart failure are at elevated risk for harm when extreme storms threaten and strike their communities. Individuals with compromised heart function require customized hurricane protection and preparedness approaches. We provide mitigation strategies for providers and their teams, as well as the patients themselves to ensure their safety and uninterrupted access to healthcare resources and quality care during hurricane impact and in the aftermath.


Subject(s)
Cyclonic Storms , Heart Failure , Climate Change , Heart Failure/therapy , Humans
11.
J Card Surg ; 36(9): 3405-3409, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1258956

ABSTRACT

The coronavirus 2019 disease (COVID-19) affected 125 million people worldwide and caused 2.7 million deaths. Some comorbidities are associated with worse prognosis and left ventricular assist device (LVAD) recipients are probably part of this high-risk population. We report a 31-year-old male patient who developed COVID-19 during LVAD implantation. His postoperative period was complicated by severe pneumonia and mechanical ventilation (MV) leading to right ventricular failure (RVF) and inotrope necessity. He experienced multiple complications, but eventually recovered. We present a systematic review of LVAD recipients and COVID-19. Among 14 patients, the mean age was 62.7 years, 78.5% were male. A total of 5 patients (35.7%) required MV and 3 patients (21.4%) died. A total of 2 patients (14.2%) had thromboembolic events. This case and systematic review suggest LVAD recipients are at particular risk of unfavorable outcomes and they may be more susceptible to RVF in the setting of COVID-19, particularly during perioperative period.


Subject(s)
COVID-19 , Heart Failure , Heart-Assist Devices , Ventricular Dysfunction, Right , Adult , Heart Failure/complications , Heart Failure/therapy , Heart-Assist Devices/adverse effects , Humans , Male , Middle Aged , Retrospective Studies , SARS-CoV-2 , Treatment Outcome
12.
Eur Heart J Case Rep ; 5(3): ytaa447, 2021 Mar.
Article in English | MEDLINE | ID: covidwho-1145164

ABSTRACT

BACKGROUND: The outbreak of coronavirus disease 2019 (COVID-19) exposes vulnerable patients to high risk of mortality. Patients with left ventricular assist device (LVAD) usually have symptoms such as cough, fever, and shortness of breath because of their cardiac condition and comorbidity, therefore these related symptoms challenge the correct diagnosis in time within the COVID-19 pandemic. CASE SUMMARY: We report two case studies of patients with LVAD in whom COVID-19 related symptoms were overlapped by their cardiac status and comorbidities. In the first case, the patient was admitted for suspicion of COVID-19 due to cough and shortness of breath for 1 month. The blood test evocated a high index of suspicion of COVID-19. The nasopharyngeal test for COVID-19 performed on admission and at Day 2 was inconclusive for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), but the test obtained on Day 3 of admission was positive, whereas computed tomography confirmed the diagnosis of COVID-19. This patient developed acute respiratory distress syndrome (ARDS) and nasal epistaxis within 48 h during hospitalization. The ARDS was treated by non-invasive ventilation and probabilistic antibiotics for 3 days and resulted significant improvement. The nasal epistaxis due to international normalized ratio increase was treated by nasal packing and vitamin K antagonist was switched to parenteral heparin infusion. The patient was kept hospitalized for 1 month for further supportive treatment. In the second case, the patient was admitted for recurrent anaemia due to melaena, the patient was tested for COVID-19 because of new-onset symptoms of cough and rhinorrhoea. The first nasopharyngeal test was positive, and sudden increase of anticoagulation status was noted in the setting of gastrointestinal bleeding. The anticoagulation status was controlled by parenteral heparin infusion, and the melaena was disappeared at Day 3. The moderate dyspnoea of the patient was quickly improved with nasal oxygen delivery for 4 days. The patient was discharged at Day 5. DISCUSSION: COVID-19 specific symptoms are challenging to distinguish in patients with LVADs, although radiological evidence can be beneficial in the COVID-19 diagnosis. We also observed the need for precise anticoagulation control to avoid bleeding or thrombotic events in these patients.

13.
Heart Fail Rev ; 27(1): 235-238, 2022 01.
Article in English | MEDLINE | ID: covidwho-1023339

ABSTRACT

The COVID-19 pandemic underscored our healthcare system's unpreparedness to manage an unprecedented pandemic. Heart failure (HF) physicians from 14 different academic and private practice centers share their systems' challenges and innovations to care for patients with HF, heart transplantation, and patients on LVAD support during the COVID-19 pandemic. We discuss measures implemented to alleviate the fear in seeking care, ensure continued optimization of guideline directed medical therapy (GDMT), manage the heart transplant waiting list, continue essential outpatient monitoring of anticoagulation in LVAD patients and surveillance testing post-heart transplant, and prevent physician burnout. This collaborative work can build a foundation for better preparation in the face of future challenges.


Subject(s)
COVID-19 , Heart Failure , Heart Transplantation , Heart-Assist Devices , Heart Failure/therapy , Humans , Pandemics , SARS-CoV-2
14.
JACC Case Rep ; 2(9): 1365-1367, 2020 Jul 15.
Article in English | MEDLINE | ID: covidwho-988186

ABSTRACT

Shared decision making with patients in advanced heart failure is critical when making decisions on therapies such as left ventricular assist device implantation and cardiac transplantation. We describe a case wherein the risks of coronavirus disease-2019 affected the decision of a patient regarding proceeding with cardiac transplantation. (Level of Difficulty: Beginner.).

15.
JACC Case Rep ; 2(14): 2265-2269, 2020 Nov 18.
Article in English | MEDLINE | ID: covidwho-933190

ABSTRACT

In the COVID-19 era, the heart failure community has witnessed an unprecedented reduction in heart failure-related patient visits and hospitalizations. Social distancing measures present a dilemma for patients with heart failure who require frequent surveillance of volume status and vital signs to minimize heart failure-related symptoms and hospitalizations. With the rise of telemedicine comes an increased focus on remote monitoring technologies. This report describes use of a multisensor device algorithm in implantable cardioverter defibrillator devices by Boston Scientific, called HeartLogic. We present 2 cases of patients with advanced heart failure who were actively surveilled by the HeartLogic device algorithm to guide care. (Level of Difficulty: Beginner.).

17.
Heart Lung ; 49(6): 688-691, 2020.
Article in English | MEDLINE | ID: covidwho-722737

ABSTRACT

COVID-19 is impacting the cardiovascular community both here in the United States and globally. The rapidly emerging cardiac complications have heightened implications for those with underlying cardiovascular disease. We describe an early case of COVID-19 in a left ventricular assist device recipient in the United States. We discuss our clinical management during the initial admission, outpatient management, and a unique complication of this disease over a 40-day disease course.


Subject(s)
Coronavirus Infections , Heart-Assist Devices , Pandemics , Pneumonia, Viral , Betacoronavirus , Blood Pressure/physiology , COVID-19 , Coronavirus Infections/diagnosis , Coronavirus Infections/physiopathology , Coronavirus Infections/therapy , Female , Heart Rate/physiology , Humans , Middle Aged , Pneumonia, Viral/diagnosis , Pneumonia, Viral/physiopathology , Pneumonia, Viral/therapy , SARS-CoV-2
18.
JACC Case Rep ; 2(9): 1347-1350, 2020 Jul 15.
Article in English | MEDLINE | ID: covidwho-574788

ABSTRACT

A 50-year-old male presented with atrial flutter 25 days after heart and kidney transplantation. Rejection was excluded, but he developed severe COVID-19 infection with cardiac allograft dysfunction. Despite continued corticosteroid and tacrolimus therapy, he remained aviremic. Respiratory and myocardial functions recovered after a week of mechanical ventilation. The cardiomyopathy was stress induced. (Level of Difficulty: Advanced.).

20.
JACC Case Rep ; 2(9): 1315-1320, 2020 Jul 15.
Article in English | MEDLINE | ID: covidwho-399793

ABSTRACT

As health systems worldwide grapple with the coronavirus disease-2019 (COVID-19) pandemic, patients with durable LVAD support represent a unique population at risk for the disease. This paper outlines the case of such a patient who developed COVID-19 complicated by a "cytokine storm" with severe acute respiratory distress syndrome and myocardial injury and describes the challenges that arose during management.

SELECTION OF CITATIONS